地下室樓板不連續(xù)對構(gòu)件受力的影響分析
發(fā)布時間:2018-01-16 01:35
本文關(guān)鍵詞:地下室樓板不連續(xù)對構(gòu)件受力的影響分析 出處:《建筑結(jié)構(gòu)》2017年S2期 論文類型:期刊論文
更多相關(guān)文章: 地下室樓板不連續(xù) 大開洞 錯層 施工后澆帶
【摘要】:地下室樓板不連續(xù)包括樓板大開洞、錯層、設(shè)置施工后澆帶等三種情況,采用有限元計算模型,詳細分析了樓板不連續(xù)對構(gòu)件內(nèi)力的影響。通過分析得出如下結(jié)論:樓板大開洞且洞口長度與洞邊距之比L/S大于1、樓板錯層、設(shè)置后澆帶時,應(yīng)采用可以考慮樓板變形的有限元軟件計算構(gòu)件內(nèi)力;樓板錯層、縱橫設(shè)置多道后澆帶的中間區(qū)域,構(gòu)件內(nèi)力較大開洞時增大更多,設(shè)計更應(yīng)引起足夠重視。
[Abstract]:The discontinuity of basement floor includes three kinds of cases, such as large opening of floor, staggered floor and setting up construction post-pouring belt. The finite element calculation model is adopted. The influence of floor discontinuity on the internal force of the member is analyzed in detail. The following conclusions are drawn: the ratio of the opening length of the floor to the margin of the hole is greater than 1, and the floor is staggered, when the post-pouring zone is set. The finite element software should be used to calculate the internal force of the member. If the floor is staggered and the middle area of the multi-channel post-pouring zone is arranged vertically and horizontally, the internal force of the member increases more when the opening is larger, and the design should be paid more attention to.
【作者單位】: 佛山市嶺南建筑設(shè)計咨詢有限公司;
【分類號】:TU93
【正文快照】: 0引言隨著社會的發(fā)展,城市中建造了越來越多的地下室,并且因地下室使用功能的需要或施工原因,出現(xiàn)較多樓板不連續(xù)的情況,如地下室作為商業(yè)使用設(shè)置的中庭導(dǎo)致樓板出現(xiàn)較多大開洞、車道設(shè)置或使用功能的某些需要造成樓板錯層、因結(jié)構(gòu)超長或分期施工而設(shè)置的后澆帶令各區(qū)域樓板