14923例單采血小板細(xì)菌檢測結(jié)果分析
[Abstract]:Objective in order to reduce bacterial contamination of platelets collected by single sample, bacterial detection was carried out on some platelets supplied to clinical patients to ensure the safety of clinical blood. Methods single platelets were detected by Bac T/ALERT 3D 240 automatic microbial detection system, aerobic culture bottle (BPA) and anaerobic culture bottle (BPN). After 7 days of culture, platelets grew aseptically. Results A total of 14 923 bags of platelets were detected during the past six years. Among them 17 cases were found to have bacterial growth and the positive rate was 0. 11%. There were 9 cases (53%) of specific anaerobic bacteria and 8 cases (47%) of aerobic bacteria. Conclusion despite the application of advanced blood culture techniques and compliance with new quality standards, bacterial contamination and septic transfusion reaction are still important risks for platelet transfusion. Therefore, it is necessary to improve the detection technology of bacterial contamination, improve the quality control procedures, and gradually establish the PLT transfusion safety monitoring system.
【作者單位】: 上海市血液中心;
【分類號(hào)】:R446.1
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 徐學(xué)新,韓海心,王青改,張海娟,梁軍;單采血小板與手工血小板輸注臨床療效比較[J];職業(yè)與健康;2003年02期
2 黃飛;單采血小板保存7天:體外研究報(bào)道[J];國外醫(yī)學(xué).輸血及血液學(xué)分冊;2003年02期
3 李善清;葉有玩;楊兵;;冰凍單采血小板在治療彌散性血管內(nèi)凝血中的療效[J];熱帶醫(yī)學(xué)雜志;2007年07期
4 申春梅;劉洪艷;祝玉美;;關(guān)于單采血小板的問題與對策[J];中國社區(qū)醫(yī)師(綜合版);2007年19期
5 呂毅;郝寶嵐;王艷;林常青;邵樹軍;周麗莉;王書鋒;;手工分離血小板與單采血小板質(zhì)量及輸注療效的對比研究[J];中國輸血雜志;2008年09期
6 武立新;高守華;;獻(xiàn)血者單采血小板3d后機(jī)體不適46例[J];實(shí)用醫(yī)藥雜志;2008年10期
7 郝寶嵐;呂毅;邵樹軍;董曉峰;任磊;;單采血小板與手工分離血小板的質(zhì)量比較[J];河南醫(yī)學(xué)研究;2010年02期
8 常在娟;徐力東;;單采血小板保存過程中質(zhì)量評價(jià)的研究[J];中國輸血雜志;2010年S1期
9 伏春琴;;單采血小板失敗20例原因分析[J];當(dāng)代醫(yī)學(xué);2012年04期
10 沈莉;李建民;侯亞萍;張靜;韓俊虎;張燕;張蕾;;血小板校準(zhǔn)系數(shù)的調(diào)整對單采血小板制品質(zhì)量影響的探討[J];中國輸血雜志;2012年S1期
相關(guān)會(huì)議論文 前10條
1 林宏;孫東明;蘭學(xué)晶;;單采血小板2個(gè)治療量儀器選擇分析[A];中國輸血協(xié)會(huì)第五屆輸血大會(huì)論文專集(摘要篇)[C];2010年
2 林宏;;無菌接管機(jī)的應(yīng)用探討[A];中國輸血協(xié)會(huì)第五屆輸血大會(huì)論文專集(摘要篇)[C];2010年
3 常在娟;徐力東;;單采血小板保存過程中質(zhì)量評價(jià)的研究[A];中國輸血協(xié)會(huì)第五屆輸血大會(huì)論文專集(摘要篇)[C];2010年
4 張宏;葉小演;孫鳳杰;孔令魁;劉怡;陳悅康;田怡;;影響無償志愿捐獻(xiàn)單采血小板的因素調(diào)查[A];中國輸血協(xié)會(huì)第三屆輸血大會(huì)論文專輯[C];2004年
5 張國清;楊玉發(fā);饒美瓊;;心理護(hù)理對單采血小板獻(xiàn)血者的影響[A];中國輸血協(xié)會(huì)第四屆輸血大會(huì)論文集[C];2006年
6 張獻(xiàn)清;穆士杰;孫文利;夏愛軍;;保存前去白細(xì)胞單采血小板的臨床應(yīng)用[A];中國輸血協(xié)會(huì)第三屆輸血大會(huì)論文專輯[C];2004年
7 賴風(fēng)雷;陳火玲;楊南;王麗;;單采血小板采前后血小板功能評價(jià)的必要性[A];中國輸血協(xié)會(huì)第三屆輸血大會(huì)論文專輯[C];2004年
8 徐朝霞;譚虹;黃可;;多次采血后獻(xiàn)血者血小板變化的觀察[A];中國輸血協(xié)會(huì)第四屆輸血大會(huì)論文集[C];2006年
9 金燕萍;朱敏華;郭炳申;;單采血小板在外科手術(shù)中的應(yīng)用[A];中國輸血協(xié)會(huì)第三屆輸血大會(huì)論文專輯[C];2004年
10 叢培芳;張永征;李穎;張燕華;;單采血小板安全采集量研究[A];中國輸血協(xié)會(huì)第四屆輸血大會(huì)論文集[C];2006年
相關(guān)博士學(xué)位論文 前1條
1 歐陽錫林;薄片法血小板快速凝集實(shí)驗(yàn)的建立及應(yīng)用研究[D];中國人民解放軍軍醫(yī)進(jìn)修學(xué)院;2010年
相關(guān)碩士學(xué)位論文 前2條
1 鄒艷艷;烏魯木齊市血液中心臨床血小板用量動(dòng)態(tài)平衡模型的建立[D];新疆醫(yī)科大學(xué);2009年
2 李靜;微粒型血小板干粉制劑的制備及其促進(jìn)小鼠皮膚創(chuàng)面愈合的實(shí)驗(yàn)研究[D];第三軍醫(yī)大學(xué);2009年
,本文編號(hào):2229632
本文鏈接:http://sikaile.net/huliyixuelunwen/2229632.html